sup_izq
sup_der
inf_der
Product view 1
Product view 2
Top left
Top right
Bottom right
Image

PLC Expansion Module / 16 Relay Outputs / AC-DC Dry Contact / 250V AC - 30V DC / 2A per Channel / Push-type Terminals / DIN Rail Mounting

  • 16 relay outputs with mechanical dry contact
  • Dual AC/DC control (250V AC, 30V DC)
  • 2A load capacity per resistive point
  • 100,000-cycle service life at full load
  • 0.98 in (25mm) slim design with DIN rail mounting
  • Tool-free push-type terminals for wiring
ModelL02S-16EYR
BrandCOOLMAY
SAT32151703
1 year of warranty

Sign in to see special prices

Sign in

Specifications

Coolmay model: L02S-16EYR

The L02S-16EYR expansion module is a high-density device designed for L02/L02S series PLC systems, providing 16 digital outputs via mechanical dry contact relays. This module allows versatile control of both alternating current (AC) and direct current (DC) loads, with the capacity to handle up to 250V AC or 30V DC and 2A per output point. The "S" version incorporates significant improvements in durability, isolation, and terminal design, including quick-pressure terminals that require no tools for wiring. With a 0.98 in (25 mm) wide slim design and standard DIN rail mounting, this module offers maximum flexibility for industrial applications requiring control of inductive and resistive loads with full galvanic isolation between the power stage and the bus logic.

General Features

  • Type: PLC expansion module
  • Function: 16 digital relay outputs
  • Contact: Mechanical dry contact
  • Compatibility: L02 and L02S Series
  • Mounting: 1.4 in (35mm) DIN rail
  • Terminals: Push-type (tool-free)
  • Isolation: Full galvanic
Output Specifications
  • Channels: 16 output points
  • Type: Relay (mechanical dry contact)
  • AC Voltage: Maximum 250V AC
  • DC Voltage: Maximum 30V DC
  • Current: 2A per point (resistive load)
  • Service life: ~100,000 cycles at full load
  • Switching frequency: Maximum 1Hz recommended
Performance and Electrical
  • Response time OFF→ON: < 10 ms
  • Response time ON→OFF: < 10 ms
  • Bus power supply: Supplied by L02/L02S CPU
  • Bus consumption: 100mA (5V DC)
  • Indicators: 16 green LEDs + RUN/ERR
  • Isolation: Full mechanical and galvanic
  • Addressing: Automatic and sequential
Dimensions and Physical
  • Width: 0.98 in (25 mm) (slim design)
  • Height: 3.54 in (90 mm)
  • Depth: 3.15 in (80 mm)
  • Terminals: Double-row push-type block
  • Mounting: 1.4 in (35mm) DIN rail (snap-in)
  • S Advantage: Anti-vibration structure
  • Safety: Improved isolation
Applications
  • 110V/220V AC contactor coils
  • AC solenoids and lamps
  • 24V DC >0.5A valves and devices
  • Highly inductive loads
  • Systems with mixed AC/DC voltages

*Recommended: use of arc suppressors (RC for AC) or flyback diodes (for DC)

S Version Differences
  • Improved contact durability
  • More efficient terminal design
  • Reinforced anti-vibration structure
  • Terminals that prevent thermal loosening
  • Improved safety isolation
  • CPU protection against power failures